The Every-2-Hours Shift Checklist

Consult http://www-boone.fnal.gov/operation-public/monitorproceedure.html for help filling out this checklist

Beginning of Shift

Your name: Date:

Sunday Day Shift: Fill out the Beam Permit Checklist.

Owl Shift Only: Begin a new study in the MiniBooNE Beamline e-log:

  1. “End Studies” for previous period in the MiniBooNE Beamline e-log (shift summary is optional).

  2. “Start Studies” in the MiniBooNE Beamline e-log (“studier” can be “MiniBooNE”, title can be anything).

Day Shift Only: Put “air activation” and “water level” plots for the past day in the MiniBooNE Beamline e-log.

Call MCR, give them your name, and tell them you are on shift at MiniBooNE.

Name of the MCR operator you spoke to:

Did you read the MiniBooNE e-log and the MCR e-log for the past shift?

Time: Current run number:

  1. Beam quality over the last 2 hours (from MCR e-log):

  2. Collider complex running mode (e.g., stacking):

  3. Device readings: B:BPL5MA E:MBRATE

  4. (record averages E:LM870 E:LM875B

  5. from Lumberjack) E:WTLVL

  6. Target BPMs: E:VP875 E:HP875

  7. (Lumberja ck average) E:VPTGTL E:HPTGTL

  8. Highest fractional Booster losses:

  9. Which L/S section?

  10. Are there any environmental alarms activated?

  11. Are Standard Monitoring Histograms/Distributions O.K.?

  12. Is ACNET incrementer incrementing?

  13. Is the run duration less than 8 hours?

  14. Are any DAQ-log or Nearline-log messages red?

  15. Is heartbeat steady?

  16. Are there any red buttons from the Horn & Target Mon. System?

  17. Is horn counter incrementing?

  18. Does “Mean time nu Candidate” for current.his look reasonable?


Two hours on shift

Time: Current run number:

  1. Beam quality over the last 2 hours (from MCR e-log):

  2. Collider complex running mode (e.g., stacking):

  3. Device readings: B:BPL5MA E:MBRATE

  4. (record averages E:LM870 E:LM875B

  5. from Lumberjack) E:WTLVL

  6. Target BPMs: E:VP875 E:HP875

  7. (Lumberja ck average) E:VPTGTL E:HPTGTL

  8. Highest fractional Booster losses:

  9. Which L/S section?

  10. Are there any environmental alarms activated?

  11. Are Standard Monitoring Histograms/Distributions O.K.?

  12. Is ACNET incrementer incrementing?

  13. Is the run duration less than 8 hours?

  14. Are any DAQ-log or Nearline-log messages red?

  15. Is heartbeat steady?

  16. Are there any red buttons from the Horn & Target Mon. System?

  17. Is horn counter incrementing?

  18. Does “Mean time nu Candidate” for current.his look reasonable?


Four hours on shift

Time: Current run number:

  1. Beam quality over the last 2 hours (from MCR e-log):

  2. Collider complex running mode (e.g., stacking):

  3. Device readings: B:BPL5MA E:MBRATE

  4. (record averages E:LM870 E:LM875B

  5. from Lumberjack) E:WTLVL

  6. Target BPMs: E:VP875 E:HP875

  7. (Lumberja ck average) E:VPTGTL E:HPTGTL

  8. Highest fractional Booster losses:

  9. Which L/S section?

  10. Are there any environmental alarms activated?

  11. Are Standard Monitoring Histograms/Distributions O.K.?

  12. Is ACNET incrementer incrementing?

  13. Is the run duration less than 8 hours?

  14. Are any DAQ-log or Nearline-log messages red?

  15. Is heartbeat steady?

  16. Are there any red buttons from the Horn & Target Mon. System?

  17. Is horn counter incrementing?

  18. Does “Mean time nu Candidate” for current.his look reasonable?


Six hours on shift

Time: Current run number:

  1. Beam quality over the last 2 hours (from MCR e-log):

  2. Collider complex running mode (e.g., stacking):

  3. Device readings: B:BPL5MA E:MBRATE

  4. (record averages E:LM870 E:LM875B

  5. from Lumberjack) E:WTLVL

  6. Target BPMs: E:VP875 E:HP875

  7. (Lumberja ck average) E:VPTGTL E:HPTGTL

  8. Highest fractional Booster losses:

  9. Which L/S section?

  10. Are there any environmental alarms activated?

  11. Are Standard Monitoring Histograms/Distributions O.K.?

  12. Is ACNET incrementer incrementing?

  13. Is the run duration less than 8 hours?

  14. Are any DAQ-log or Nearline-log messages red?

  15. Is heartbeat steady?

  16. Are there any red buttons from the Horn & Target Mon. System?

  17. Is horn counter incrementing?

  18. Does “Mean time nu Candidate” for current.his look reasonable?


End of shift:

Did you put beam summary plot in the current MiniBooNE beamline e-log?
Did you leave the shifter pager at the control room?

Did you log out from CRL?

Revised: 02/15/04